Solution Summary: Lead Encapsulating Compounds
Description:
Lead encapsulation is a lead abatement method approved by the US Department of Housing and Urban Development (HUD). It is most frequently used to cover and seal lead-based paint in good condition so that no paint chips are released into the environment. It is a good option for projects where the full removal of lead-based paint is not practical, such as on the facades of historic buildings. Lead encapsulating compounds (LECs) are available in a liquid or adhesive form, which can be reinforced with fabrics.
LECs are appropriate for sealing surfaces that are not frequently affected by friction or movement. Before deciding on a lead abatement method, it is important to identify and examine the surfaces you want to abate. LECs may be a good option for surfaces covered in lead-based paint that are not flaked, chipped, subject to friction or movement (such as a floor or doorjamb), or otherwise likely to deteriorate. Encapsulants are not appropriate for accessible/mouthable edges that small children can bite. Encapsulation may also include other forms of durable material that enclose lead-based paints such as vinyl tiles or sheets on floors, drywall (glued or permanently affixed), or other dust impermeable materials that permanently prevent access to the surface.
If LECs are right for your project, there are a variety to choose from. Make sure you follow the manufacturer’s specifications carefully, especially in terms of recommended thickness (usually measured in mils, or thousandths of an inch) and cure time.
LBC Type III-Industrial Lead Encapsulant from Fiberlock Technologies
- Cost: $266 (verified 3/28/2019)
- Size: 5 gallons
- Application: Brush, roller, or spray
- Recommended application thickness: 14 mils wet
- Lifespan: 20 years (indoors)
- Ventilation/Respiratory Protection Required: Yes
Lead Stop® Lead Encapsulating Compound from Dumond
- Cost: $227 (verified 3/28/2019)
- Size: 5 gallons
- Application: Brush, roller, or spray
- Recommended application thickness: 14 mils wet
- Lifespan: 20 years (indoors)
- Ventilation/Respiratory Protection Required: Yes
Risks Addressed:
How Risks are Reduced:
Lead encapsulating compound (LEC) is painted, rolled, or sprayed over lead-based paint. Once it dries and is allowed to cure, it creates a barrier that prevents residents from coming into contact with the lead paint underneath. When applied correctly and inspected regularly, some LEC products can last up to 20 years indoors.
- Perform patch test – Before applying LEC, you must perform a patch test on each surface you want to abate. Only surfaces that pass a patch test can be encapsulated. Each building component must be patch tested individually. So, if you want to abate a room that has lead-based paint on the walls, woodwork, and fireplace, you must perform three separate patch tests. Any components that fail the patch test cannot be abated with LEC. Prepare an inconspicuous area about 6 x 6 inches large. Apply the encapsulant according to the manufacturer’s specifications. If possible, let the LEC cure completely. Once it is ready, inspect the surface. Extensive crackling, bubbling, or blistering means that surface has failed the patch test. If the patch looks like it is in good condition, perform an X-cut test by using a sharp blade to cut an ‘X’ that is at least 1.5 inches tall and 1.5 inches wide into the encapsulant, cutting smoothly all the way through every paint layer at a right angle. If you make a mistake, do not re-cut, and make another X in a different part of the patch. Use the blade to try and separate the LEC from the top coat of paint. If you can pull more than a half inch of LEC away from the top coat, that surface has failed the test. A half inch or less is acceptable.
- Apply LEC – Once you are sure a surface is appropriate for LEC, clean and prepare it in the same way you did for the successful patch test. Make sure the area you are working in is well-ventilated. Check the Safety Data Sheet (SDS) for the LEC product you have selected, and be sure to use adequate respiratory protection. Keep in mind that not all SDSs are 100% accurate. Apply the LEC to the thickness specified by the manufacturer. Allow it to dry and cure. Most LECs work best from 40-95° F. Although many LECs are off-white, some are clear or can be tinted. Once the LEC has cured (up to 30 days), it is safe to paint over.
- Monitor LEC – Inspect the LEC visually at one month and six months post-application. After that, monitoring can be reduced to at least once every two years as long as the surface remains in good condition. Keep in mind that all LECs have an expiration date according to the manufacturer’s specifications.
Additional Considerations:
There are two rules set forth by the Environmental Protection Agency (EPA) for work that may cause lead exposure. The first is the Lead Renovation, Repair and Painting Rule, which governs projects where the primary goal is renovation. When the primary goal is simply lead abatement, the project is covered by the Lead Abatement Rule. This document focuses on the requirements of LEC use in the Lead Abatement Rule.
Since LECs isolate workers and residents from lead but do not eliminate it, recordkeeping is especially important for any future renovation, abatement, or demolition work. Make sure to document every step of the process and follow the local regulations of your city and state, especially if they are more stringent than federal regulations. These regulations may include training requirements. For more detailed instructions on the use and maintenance of LECs, please visit https://www.hud.gov/sites/documents/LBPH-15.PDF
Contributors:
Sara Brooks, MPH: CPWR - The Center for Construction Research and Training
Mike Kassman, MAHP, CHST, PA-AIC, APT: CPWR - The Center for Construction Research and Training
James Platner, Ph.D, CIH
Availability
Dumond
To obtain information, visit Lead Stop® Lead Encapsulating Compound
or contact 609-655-7700
Fiberlock Technologies
To obtain information, visit LBC Type III-Industrial Lead Encapsulant
or contact 843-964-4471 jtrowman@icp-construction.com